Lab 1 - Reaction Stoichiometry
Purpose
To determine the stoichiometry of acid-base reactions by measuring temperature changes which accompany them.Goals
-
•To learn to use the MicroLab Interface.
-
•To practice generating reaction tables.
-
•To determine the limiting reagent in a reaction through a measured quantity.
Introduction
In this lab, you will be investigating reaction stoichiometry by doing a series of mixing experiments using acids and bases in different amounts. By following temperature changes upon mixing, you will be able to relate the amount of heat given off in the reaction to the moles of acid and base that react. The first set of experiments uses the neutralization of HCl with sodium hydroxide:( 1 )
HCl(aq) + NaOH(aq) → NaCl(aq) + H2O
( 2 )
H3PO4(aq) + 3 NaOH(aq) → Na3PO4(aq) + 3 H2O
( 3 )
2 Al + 6 HCl → 2 AlCl3 + 3 H2
( 4 )
moles HCl needed = 65.5 g Al ×
×
= 7.28 mol HCl
1 |
27.0 |
6 mol HCl |
2 |
( 5 )
grams AlCl3 produced = 65.5 g Al ×
×
×
= 323 g AlCl3
1 |
27.0 |
2 |
2 |
133 g AlCl3 |
1 |
( 6 )
grams AlCl3 produced = 6.00 mol HCl ×
×
= 266 g AlCl3
2 |
6 |
133 g AlCl3 |
1 |
( 7 )
Percent yield =
× 100%
actual yield (g or mol) |
theoretical yield (g or mol) |
( 8 )
255 |
266 |
-
-
−sign) and the product side increases (the + sign). IT IS ON THIS LINE WHERE THE REACTION STOICHIOMETRY AND LIMITING REACTANT ARE ACCOUNTED FOR. This has been indicated in the table by the use of all of the HCl and the use of the stoichiometric amount of Al along with the stoichiometric equivalents of the products based on the HCl being the limiting reactant.
( 9 )
20. mL NaOH solution ×
= 26 mmol NaOH
1.3 mmol NaOH |
1.0 mL solution |
Equipment
Reagents
Safety
You will be working with hydrochloric acid, HCl(aq); phosphoric acid, H3PO4(aq); and NaOH(aq). These chemicals are corrosive. If you spill one of them on a surface, wipe it up with paper towels and rinse with water, being careful not to touch the liquid. If you spill some on yourself, immediately rinse the area with lots of water. If any gets in your eyes, flush them with water at the eyewash and have someone notify the TA.Waste Disposal
The solutions used in this experiment can be flushed down the sink with plenty of water.Prior to Class
Please read the following sections of Lab Safety and Practices: Good Lab Practices and Measurements. Please read the following section in Lab Equipment: Volumetric Glassware. Please review the following video: Safety. Please complete WebAssign prelab assignment. Check your WebAssign Account for due dates. Students who do not complete the WebAssign prelab are required to bring and hand in the prelab worksheet.Lab Procedure
Please print the worksheet for this lab. You will need this sheet to record your data and write out calculations.1
Open the MicroLab program.
2
Calibrate the thermistor as described in the MicroLab instructions provided in the lab.
3
After the calibration is complete, set the MicroLab collection increment to 2 seconds using the instructions provided.
4
In separate appropriately labeled 150 mL beakers, obtain the total amount of acid and base solutions you will need for each set of experiments: 60 mL HCl, 45 mL H3PO4 and 150 mL NaOH. Record their concentrations in Table A.
5
Label a graduated cylinder for acid, another for base and a third for deionized water. Use them consistently for the liquid designated. For each experiment, add the NaOH solution and the deionized water together in a 150 mL beaker, and immerse the thermistor part way into the liquid being careful not to touch the thermistor to the bottom or sides of the vessel.
6
Add the appropriate amount of NaOH solution (20 mL) and deionized water (20 mL) for the first run to a 150 mL beaker. Do not, at this point, handle the beaker since we only want to measure the heat evolved from the reaction. Use a clamp to hold the thermistor in place in the beaker to prevent it from touching the bottom and prevent the beaker from tipping over.
7
Measure the initial temperature of the base (NaOH solution, diluted with water). You may need to wait ~2 minutes to be sure the temperature has stabilized. Record its temperature to the nearest 0.01°C in Table B.
8
Add the appropriate amount of acid solution and swirl the beaker gently. If you swirl too vigorously, you may spill the acid and base on your hand. Do not stir with the thermistor as it can easily break. After the temperature stops changing (~30 sec), stop the temperature collection program. Record this final temperature to the nearest 0.01°C in Table B. Note: After stabilizing, the temperature may slowly, over the course of many minutes, decrease toward room temperature. Record the first stable temperature as your final temperature.
9
Dispose of the solution from the first run and rinse the reaction beaker and thermistor thoroughly with deionized water from your squirt bottle.
10
Obtain temperature change data for the other 5 mixing experiments by repeating steps 6 - 9. Remember to record both your initial and final temperatures for each experiment in Tables B and C.
11
Close the MicroLab software. Rinse all of your glassware with water, dry it and return it to the set-up area where you found it.
12
Before leaving, enter your results in the WebAssign In-Lab assignment. If all results are scored as correct, log out. If not all results are correct, try to find the error or consult with your lab instructor. When all results are correct, note them and log out of WebAssign. The In-Lab assignment must be completed by the end of the lab period. If additional time is required, please consult with your lab instructor.